Hanwei Wet-type Direct-reading Remote Water Meter
Specifications
Details
Material: Ductile iron and cast copper
Accuracy:
Maximum allowable error @ Q1~Q2: ±5%.
Maximum allowable error @ Q3-Q4: water temperature 0.1~30℃, max permissible error: ± 2%; water temperature >30℃, max permissible error ± 3%.
Sensor type: Photoelectricity direct reading type
Communication type: Mbus/RS485
Power Supply: DC28~42V
Description
Wet-type direct-reading remote water meter (hereinafter referred to as WDR water meter) is Hanwei’s self-developed direct-reading remote water meter that is convenient for remote meter reading and control for the actual needs of daily water consumption.
It adopts M-BUS∕RS485 bus mode communication to realize the remote direct reading of the water meter, effectively avoiding the door-to-door meter reading by the water company/bureau.
WDR water meter also has a valve control function (optional), which is convenient for the water company/bureau to control the water consumption of the direct-reading remote water meter, making remote meter reading and control more convenient and reliable, while saving manpower, material and financial resources. , effectively increasing productivity.
Features
Adopt direct reading patented technology to realize digital remote transmission of data.
Infrared radiation mode is adopted to enhance the anti-interference ability.
Fully sealed waterproof treatment, protection grade IP68.
Housing material can be ductile iron, cast copper or stainless steel.
With low power consumption design, power supply is only required for meter reading.
Use Mbus/RS485 bus to communicate, and cooperate with the self-developed meter reading system to realize meter reading automation.
Application
Residential & Commercial buildings
Old community renovations
Schools, urban and rural water supply
Urban road greening water
Farmland irrigation etc.
Specifications
| Mechanical part | |||
| Parameter | unit | Value | |
| Nominal diameter (DN) | mm | 15 | 20 |
| Minimum flow (Q 1 ) | m3/h | 0.025 | 0.04 |
| Boundary Flow (Q 2 ) | m3/h | 0.04 | 0.06 |
| Common flow (Q 3 ) | m3/h | 2.5 | 4 |
| Overload flow (Q 4 ) | m3/h | 3.125 | 5 |
| Q 3 /Q 1 (R) | 100 | ||
| pressure loss | 0.063MPa | ||
| Pressure Level | MAP10, normal ≤ 1.0MPa, short time ≤ 1.6MPa | ||
| water temperature | Temperature: 0.1~+45℃ ( cold water ) | ||
| Electrical part | |||
| Working Power | DC2 1 -42V (MBUS interface) | ||
| Working Current | Static current: <1.2mA , instantaneous working current for meter reading: <12mA | ||
| Ambient Temperature | Temperature: -20 ℃~+45℃ , Humidity: 0~ 100 %RH | ||
| Degree Of Protection | IP68 | ||
| Valve Function | optional | ||
| Way Of Communication | Wired M-BUS bus communication or wired RS485 communication | ||
| Communication Transmission Rate | 1200/2400/4800/9600bps optional | ||
| Communication Distance | ≤300m | ||
| Letter Of Agreement | " 188 Communication Protocol" or ModBus protocol , and the protocol can be customized | ||
| Protection Mechanism | Bus open circuit protection , short circuit protection , overvoltage protection, overcurrent protection | ||
View more about Hanwei Wet-type Direct-reading Remote Water Meter on main site