Tenmars TM-1104  700A AC/DC Transducer

Tenmars TM-1104 700A AC/DC Transducer

Category: AC/DC Transducer

Specifications
SKU
Tenmars TM-1104 700A AC/DC Transducer
Details


Application

  • Before start the test, take all precautionary measures for operator’s safety (electrical protection gloves, etc.)
  • Even if it is possible to insert / remove energized conductors from the jaws (symbol  ), de-energise (if possible) the conductors under test
  • Connect clamp’s output terminal to the inputs of the instrument to be used as indicator
  • Select the 700A desired range on clamp. The yellow LED “ON” should be on. Verify that “Low Bat” red LED it’s off. If no, open the back battery cover and replace the batteries. 
  • Verify the zero at display of instrument to be used as indicator. If no, press ZERO key on clamp before start measurement
  • Open the clamp and put the tested conductor in the center of the clamp jaws. No gap is allowed between the connections of clamp jaws. Always consider the correct connection of clamp 


 

Features

  • AC Current
  • DC Current


 

Specifications

  • Safety:IEC/EN61010-1
  • Pollution degree:2
  • Operating Temperature/Humidity:-10 ~ +50 °C
  • Storage Temperature/Humidity: -10 ~ +60 °C
  • Overvoltage Catagory:CAT III 600V
  • Max diameter of cable:30mm
  • Dimension: 175mm(L)x70mm(W)x35mm(H).
  • Weight:about 200g. (Including battery)

TECHNICAL Specifications
AC Current
Current Range Output Rang Accuracy
(45~64Hz)
Overload
Protection
700A 1mV/1A ±(2.0% Reading+5A) 800Arms
(60second)
 
DC Current
Current Range Resolution Accuracy
40Hz~65Hz
Overload Protection
700A 1mV/1A ±(2.0%Reading+5A) 800Vrms
(60second)

 


  • Read the current value in the indicator’s display

View more about Tenmars TM-1104 700A AC/DC Transducer on main site