Tenmars TM-28E TRMS AC/DC WATT Clamp Meter
Category: AC/DC Clamp Meter
Specifications
SKU
Tenmars TM-28E TRMS AC/DC WATT Clamp Meter
Details
Application
- Measuring voltage over 20V as it may cause human body electricity conduction.
- Measure AC power.
- Operating Environment: Indoor use. This instrument has been designed for using in an environment of pollution degree 2.
- Operation Altitude: up to 2000m.
- Operating Temperature & Humidity: 5℃ ~ 40℃,below 80%RH.
- Storage Temperature & Humidity: -10℃ ~ 60℃, below 70%RH.
- Fingers should hold under the protection guard of test probe.
- Category: EN 61010-1(2001)
EN 1010-2-032(2002)
CAT Ⅲ 600V
CAT Ⅱ 1000V
Features
- DC CURRENT (DCA) MEASUREMENT
- AC CURRENT (ACA) MEASUREMENT
- DC VOLTAGE (DCV) MEASUREMENT
- AC VOLTAGE (ACV) MEASUREMENT
- AC+DC WATT MEASUREMENT
- RESISTANCE MEASUREMENTS
- CONTINUITY TESTS
- FREQUENCY MEASUREMENTS
- MEASURING NON-SINUSOIDAL QUANTITY
Specifications
-
Display: 3¾digits LCD with maximum reading 3999, Plus decimal point, unit symbol indication.
-
Overload Indication: LCD will show a “OL” in the left highest position.
-
Low Battery Indication: Replace battery as LCD display “
”.
-
Sampling Rate: 2 times per second for digital display.
-
Jaws opening:Max. 36mm
-
Conductor size:Max. 35mm
-
Dimension: 218mm(L)x75mm(W)x43mm(H).
-
Weight:about 360g. (Including battery)
Electrical Specifications
DCA
|
|||
Range
|
Resolution
|
Accuracy
|
Overload
Protection |
400A
|
0.1A
|
±(1.5%+5)
|
800A rms
(60 second)
|
600A | 1A | ±(2.0%+5) |
ACA
|
|||
Range
|
Resolution
|
Accuracy
50Hz~60Hz |
Overload Protection
|
400A
|
0.1A
|
±(2.0%+5)
|
800A rms
(60 second) |
600A
|
1A
|
±(2.5%+5)
|
AC CURRENT
(TRUE RMS:From 10% to 100% of range) |
||||
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
|
40Hz~65Hz
|
65Hz~1kHz
|
|||
400A
|
0.1A
|
±(2.0%+5)
|
±(3.0%+8)
|
800A rms
(60second)
|
600A
|
1A
|
±(2.0%+5)
|
±(3.0%+8)
|
CURRENT 1 mS PEAK HOLD
|
|||
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
400V
|
0.1A
|
±(1.2%+15)
|
600V rms
|
600V
|
1A
|
±(2.5%+15)
|
DC VOLTAGE
|
|||
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
400V
|
0.1V
|
±(1.0%+3)
|
600V rms
|
600V | 1V |
AC VOLTAGE
(TRUE RMS:From 10% to 100% of range) |
||||
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
|
400V
|
0.1V
|
40Hz~400Hz
|
400Hz~2kHz
|
600V rms
|
600V
|
1V
|
±(1.2%+5)
|
±(2.0%+5)
|
VOLTAGE 1 mS PEAK HOLD
|
|||
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
400V
|
0.1V
|
±(1.5%+15)
|
600V rms
|
600V
|
1V
|
±(2.5%+15)
|
AC+DC WATT
|
||||
Range
|
Resolution
|
Accuracy
|
Frequency
|
Overload Protection
|
40KW
|
0.01KW
|
±(5.0+5)
|
0~1KHz
|
600V rms
|
400KW
|
0.1KW
|
±(5.0+5)
|
Continuity Test
|
||||
Range
|
Resolution
|
Buzzer
|
Max.Open Voitage
|
Overload
Protection |
![]() |
1Ω
|
Lower 400Ω
|
About 1.2V
|
DC 500V rms
AC500V rms |
RESISTANCE
|
||||
Range
|
Resolution
|
Accuracy
|
Max. Open Voltage
|
Overload Protection
|
4000Ω
|
1Ω
|
±(1.0%+3)
|
0.4VDC
|
600V rms
|
Frequency Test
|
||||
Range
|
Resolution
|
Accuracy
|
Max. Sensibility
|
Overload Protection
|
4KHZ
|
1HZ
|
±(0.5%+3)
|
5Vrms
|
DC600V
AC600V rms
|
40KHZ
|
10HZ
|
|||
400KHZ
|
100HZ
|
View more about Tenmars TM-28E TRMS AC/DC WATT Clamp Meter on main site