Tenmars TM-13E AC/DC Clamp Meter

Tenmars TM-13E AC/DC Clamp Meter

Category: AC/DC Clamp Meter

Specifications
SKU
Tenmars TM-13E AC/DC Clamp Meter
Details

Application

EMC:This apparatus was designed in accordance with EMC standards in force and its compatibility has been tested in accordance EN61326 (1997) + A1 (1998) + A2 (2001).

 

Features

  • Jaws opening up to 30mm.
  • The maximum conductor size is Ø30mm.
  • Safety sockets designed.
  • Data Hold.
  • Impedance in circuit is below 40Ω. The buzzer will sound.
  • Polarity Indication: Automatic polarity, “-“ display for negative input.
  • Overload Indication: LCD will show a “OL” in the left highest position.
  • Low Battery Indication : Replace battery as LCD display “BAT”.
     

Specifications

  • Display:3¾LCD with maximum reading 3999 units plus decimal point signs plus backlight
  • Sample rate:2 times/sec.
  • Jaws opening:30mm
  • Max conductor size:30mm
  • Dimension: 195mm(L)x64mm(W)x30mm(H).
  • Weight:about 240g. (Including battery)

Electrical Specifications(23℃±5℃, with RH< 75%RH )
DCA (Auto/Manual)
Range Resolution Accuracy Overload
Protection
40A 0.01A ±(2.0%+10) 600A rms
(60 second)
400A 0.1A
 
ACV (Auto/Manual)
Range Resolution Accuracy
50Hz~500 Hz
Input
Impedance
Overload Protection
400mV 0.1mV ±(1.0%+3)
40Hz~60Hz
100MΩ DC/AC
660V rms
4V 1mV ±(1.0%+3) 11MΩ
40V 10mV 10MΩ
400V 100mV
600V 1V ±(1.2%+3)
 
DCV (Auto/Manual)
Range Resolution Accuracy Input Impedance Overload
Protection
400mV 0.1mV ±(0.8%+2) 100MΩ DC/AC
660V rms
4V 1mV 11MΩ
40V 10mV 10MΩ
400V 100mV
600V 1V ±(1.0%+2)
 
Continuity
Range Buzzer Max. Open
Voltage
Overload
Protection
below 40 About-1.5VDC 600V rms
 
Resistance (Auto/Manual)
Range Resolution Accuracy Max.
Sensitivity
Overload
Protection
400Ω 0.1Ω ±(1%+5) about -1.5VDC DC/AC
600V rms
(60Second)
4KΩ 1Ω ±(1%+3) About-0.45VDC
40KΩ 10Ω
400KΩ 100Ω
4MΩ 1KΩ
40MΩ 10Ω ±(3%+3)

 