Tenmars TM-1017 400A True-RMS AC Power Clamp Meter+ Phase

Tenmars TM-1017 400A True-RMS AC Power Clamp Meter+ Phase

Category: AC Clamp Meter

Specifications
SKU
Tenmars TM-1017 400A True-RMS AC Power Clamp Meter+ Phase
Details

TM-1017  400A True-RMS AC Power Clamp Meter+ Phase


 
This apparatus conforms to safety standard EN 61010
 

Application

It can be used for CURRENT measurements on installations of over voltage category III up to 600V (voltage between phase and earth) and for VOLTAGE and FREQUENCY measurements on installations of over voltage category III up to 600V (voltage between terminals and between phase and earth).


 

Features

The apparatus can perform the following measurements:
  • AC voltage (VAC) with TRMS conversion mode.
  • DC voltage (VDC).
  • AC current (IAC) with TRMS conversion mode.
  • Harmonic AC voltage (from DC to 24h components)
  • Harmonic AC current (from 1st to 24th components).
  • Frequency with input test leads.
  • Frequency with clamp jaws.
  • Resistance.
  • Continuity test.
  • Phase rotation with only one test lead.
  • Active, reactive, apparent power and power factor measure on single-phase systems.
  • Active, reactive, apparent power and power factor measure on balanced three phase systems.
  • Active, reactive, apparent energy measurements on single-phase systems.
  • Active, reactive, apparent energy measurements on balanced three phase systems.

Specifications

  • Display:4 dgt LCD with maximum reading 9999 units plus decimal point and sign
  • Sample rate:64 samples in 20ms
  • Conversion mode:TRMS
  • Jaws opening:30mm
  • Max conductor size:30mm
  • Dimension: 205mm(L)x64mm(W)x39mm(H).
  • Weight:about 280g. (Including battery)

CHARACTERISTICS SPECIFICATIONS(23℃±5℃, below 75%RH )
DC Voltage
Range Resolution Accuracy Input impedance
0~599.9V 0.1V ±(1.0%+3dgt) 1MΩ
 
AC Voltage(TRMS)
Range Resolution Accuracy Input impedance
40~200Hz 200~400Hz
1.6~599.9V 0.1V ±(1.0%rdg+3dgt) ±(5.0%rdg+3dgt) 1MΩ
Max. Crest factor = 1.41
 
MAX / MIN / AVG / PEAK AC/DC Voltage
Function Range Resolution Accuracy Response time
MAX,MIN,AVG 10÷599.9V 0.1V ±(5.0%rdg+10dgt) 500ms
PEAK 10÷ 850V 1V ±(5.0%rdg+10dgt) 1ms
 
AC Current (TRMS)
Range Resolution Accuracy Overload protection
40÷200Hz 200÷400Hz
0.0~399.9V 0.1A ±(1.0%rdg+3dgt) ±(5.0%rdg+3dgt) 600A RMS
Max. Crest factor = 2
 
MAX / MIN / AVG / PEAK AC Current
Function Range Resolution Accuracy Response time
MAX,MIN,AVG 1.0~399.9V 0.1V ±(5.0%rdg+10dgt) 500ms
PEAK 10~800V 1V ±(5.0%rdg+10dgt) 1ms
 
Resistance and Continuity test
Range Resolution Accuracy Overload protection
0.0~499.9Ω 0.1Ω ±(1.0%rdg+5dgt) 600V AC/DC RMS
500~999Ω 1Ω
1000~1999Ω 3Ω
Instrument emits a buzzer for R<40Ω
 
Frequency (with test leads/ with jaws)
Range Resolution Accuracy Overload protection
40.0~399.9Hz 0.1Hz ±(0.5%rdg+1dgt) 600V RMS / 600A RMS
Voltage range for frequency measure, with test leads: 0.5  - 600V, with jaws: 0.5  - 400V
 
Voltage and current harmonics
Harmonic order Resolution [V], [A] Accuracy
1~15 0.1 ±(10.0%rdg+5dgt)
16~25 0.1 ±(15.0%rdg+5dgt)
ccuracy defined for: voltage≥1.6V, current≥2A
 
Power factor≥
Range Resolution Accuracy
0.20~1.00 0.01 ±3°
Accuracy defined for: sine wave, voltage 230 - 400V, current≥2A, freq. 50-60Hz
 
Active power, Reactive power, Apparent power
Range
[kW],[kVAR],[kVA]
Resolution
[kW],[kVAR],[kVA]
Accuracy
0.00~99.99 0.01 ±(3.5% rdg+3dgt)
100.0~999.9 0.1
Accuracy defined for: sine wave, voltage 230- 400V, current≥1A, freq. 50-60Hz, Pf: 0.8i - 0.8c
 
Phase sequence and phase coincidence
Range Frequency range Input impedance Overload
protection
50~600V 40-69Hz 1MΩ 600V RMS
 
MAX / MIN / AVG Resistance and Continuity test
Range Resolution Accuracy Tempo di risposta
0.0~499.9Ω 0.1Ω ±(1.0%rdg+5dgt) 1s
500~999Ω 1Ω
1000~1999Ω 3Ω
Instrument emits a buzzer for R<40Ω
 
MAX / MIN / AVG Frequency (with test leads/ with jaws)
Range Resolution Accuracy Tempo di risposta
40.0~399.9Hz 0.1Hz ±(0.5%rdg+1dgt) 1s
Max∆f/∆t =0.5Hz/s
 
MAX / MIN / AVG Active power,
Reactive power, Apparent power
Range [kW],[kVAR],[kVA] Resolution [kW],[kVAR],[kVA] Accuracy Tempo di risposta
0.1~99.99 0.01 ±(3.5%rdg+3dgt) 1s
100.0~999.9 0.1
Accuracy defined for: sine wave, voltage 230÷400V, current≥1A, freq. 50-60Hz, Pf: 0.8i÷0.8c
 
MAX / MIN / AVG Power factor
Range Resolution Accuracy Response time
0.20~1.00 0.01 ±3° 1s
Accuracy defined for: sine wave, voltage 230 - 400V, current≥2A, freq. 50-60Hz

 

View more about Tenmars TM-1017 400A True-RMS AC Power Clamp Meter+ Phase on main site