Tenmars TM-1016 AC-HVAC Clamp Phase
Category: AC-HVAC Clamp Phase
Specifications
SKU
Tenmars TM-1016 AC-HVAC Clamp Phase
Details
TM-1016 AC-HVAC Clamp Phase
This apparatus conforms to safety standard EN 61010
Application
It can be used for CURRENT, VOLTAGE and FREQUENCY measurements on installations of surge voltage category III up to 600 V, voltage between Phase and Earth (fixed installations) and for current measures up to 400A.Features
The apparatus can perform the following measurements:- AC current (IAC).
- AC uA current(I AC).
- DC uA current.(I DC).
- AC voltage (VAC).
- DC voltage (VDC).
- DC current (IDC).
- Resistance.
- Continuity Test.
- Capacitance.
- Temperature
Specifications
- Display:3 ¾ LCD with maximum reading 3999 units plus decimal point signs plus backlight
- Sample rate:2 times/sec.
- Jaws opening:30mm
- Max conductor size:30mm
- Dimension: 205mm(L)x64mm(W)x39mm(H).
- Weight:about 280g. (Including battery)
CHARACTERISTICS SPECIFICATIONS(23℃±5℃, with RH< 75%RH )
DC µA (Auto/Manual) | ||||
Range | Resolution | Accuracy | Burden Voltage | Overload Protection |
400µA | 0.1µA | ±(1.0%+2) | 500uV/uA | 0.2A/250V Fuse |
4000µA | 1µA |
AC µA (Auto/Manual) | ||||
Range | Resolution | Accuracy 50Hz~60 Hz |
Burden Voltage | Overload Protection |
400µA | 0.1µA | ±(1.2%+3) | 500µV/µA | 0.2A/250V Fuse |
4000µA | 1µA |
ACA (Auto/Manual) | |||
Range | Resolution | Accuracy 50Hz~60 Hz |
Overload Protection |
40A | 0.01A | ±(2.0%+10) | 600A rms (60 second) |
400A | 0.1A | ±(1.5%+10) |
DCV (Auto/Manual) | ||||
Range | Resolution | Accuracy | Input Impedance | Overload Protection |
4V | 1mV | ±(0.8%+2) | 11MΩ | DC/AC660V rms |
40V | 10mV | 10MΩ | ||
400V | 100mV | |||
600V | 1V | ±(1.0%+2) |
ACV (Auto/Manual) | ||||
Range | Resolution | Accuracy 50Hz~500 Hz | Input Impedance | Overload Protection |
4V | 1mV | ±(1.0%+3) | 11MΩ | DC/AC660V rms |
40V | 10mV | 10MΩ | ||
400V | 100mV | |||
600V | 1V | ±(1.2%+3) |
Resistance (Auto/Manual) | ||||
Range | Resolution | Accuracy | Max. Open Voltage | Overload Protection |
400Ω | 0.1Ω | ±(0.8%+5) | about -1.5VDC | DC/AC600V rms (60Second) |
4KΩ | 1Ω | ±(0.8%+2) | About-0.45VDC | |
40KΩ | 10Ω | |||
400KΩ | 100Ω | |||
4MΩ | 1KΩ | |||
40MΩ | 10KΩ | ±(3%+2) |
Continuity Test | |||
Range | Buzzer | Max. Open Voltage | Overload Protection |
![]() |
below 25 | About-1.5VDC | 600V rms |
Capacitance (Auto/Manual) | |||
Range | Resolution | Accuracy | Overload Protection |
4nF | 1pF | ±(3%+10) | DC/AC600V rms (60Second) |
40nF | 10pF | ||
400nF | 100PF | ||
4µF | 1nF | ||
40µF | 10nF | ||
400µF | 100nF | ||
4mF | 1µF | ±(5%+10) |
Temperature:optional temp.probe:K(CA) type. | ||
Range | Resolution | Accuracy |
°C | 1°C | -50°C~ 0°C±(1.8%+2°C) 0°C~ 500°C±(1.0%+2°C) 500°C~ 1200°C±(1.8%+2°C) |
°F | 1°F | -58°F~ 32°F±(1.8%+3°F) 32°F~ 932°F±(1.0%+3°F) 932°F~ 1999°F±(1.8%+3°F) |
The tolerance of temp. Probe excluded. |