Details
Application
This unit is a compact 3½digit digital clamp meter for measuring AC voltage, AC current, resistance, continuity and frequency. It can be operated easily and is an ideal instrument tool.Features
- Display: 3 1/2 -digit LCD with a max. reading of 1999
- Overrange indication : "1" shown on LCD
- Sampling rate: Approximate 3 times per sec.
- Error caused by improper position: 1% of reading (Note: The conductor should be placed in the
- center of the jaws to avoid this error)
- Sensor : Clamp-shape transformer for AC measurement
- Jaw opening capability : 40mm
- Max. measurable conductor:Ø37mm
Specifications
-
Dimensions:205x80x35mm(length x width x height).
-
Weight: Approximately 257 grams.(incl. Battery)
Electrical Specifications
AC Voltage
|
|||
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
200V
|
0.1V
|
±(1.2%+3)
|
DC 1000V
AC 750V rms |
750V
|
1V
|
-
Input impedance: 10MΩ
-
Frequency response: 40Hz~400Hz
-
Max. permitted input voltage: 750Vrms
AC Current
|
|||
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
20A
|
10mA
|
±(2%+5)
|
600A
(30 secs.) |
200A
|
100mA
|
||
600A
|
1A
|
±(4%+8)<6A
|
|
±(2%+5)
|
|||
±(4%+8)>590A
|
-
Response: Average, calibrated in rms of sine wave.
-
Frequency range: 50 – 60Hz
Frequency
|
|||
Range
|
Resistance
|
Accuracy
|
Overload Protection
|
2000Hz
|
1Hz
|
±(0.8%+3)
|
350Vrms
|
Resistance
|
|||
Range
|
Resistance
|
Accuracy
|
Overload Protection
|
2000Ω
|
1Ω
|
±(1.0%+2)
|
350V rms
|
Audible Continuity
|
|||
Range
|
Opencircuit voltage
|
Description
|
Overload protection
|
![]() |
<1.5V
|
If resistance is less than about 40Ω, the built-in buzzer will sound
|
350Vrms
|
Note:
When the resistance is between 400 and 1200,
the buzzer may sound or may not sound.
When the resistance is more than 1200, the buzzer will not sound.
View more about Tenmars YF-8020A AC Clamp Meter on main site