Tenmars TM-24E AC/DC Clamp Meter

Tenmars TM-24E AC/DC Clamp Meter

Category: AC/DC Clamp Meter

Specifications
SKU
Tenmars TM-24E AC/DC Clamp Meter
Details

Application

  • Measuring voltage over 20V as it may cause human body electricity conduction.
  • Measure AC power. 
  • Operating Environment: Indoor use. This instrument has been designed for using in an environment of pollution degree 2.
  • Operation Altitude: up to 2000m.
  • Operating Temperature & Humidity: 5℃ ~ 40℃,below 80%RH.
  • Storage Temperature & Humidity: -10℃ ~ 60℃, below 70%RH.
  • Fingers should hold under the protection guard of test probe.
  • Category: ICE 1010-1 CATⅡ 600V .
                     ICE 1010-1 CATⅡ 1000V .
                     ICE 1010-2-032  CATⅢ 600V .

Features

AC Current (ACA) /DC Current (DCA) measurement
  • Make sure that all the test leads are disconnected from the meter’s terminal for current measurement.
AC Voltage (ACV) /DC Voltage (DCV) measurement
  • Maxim input for DCV or ACV is 600V.
Resistance measurements
  • Before measuring the resistance, please be sure to remove power from the circuit being tested and discharge all the capacitors.
    If the reading is over range, the symbol “OL” will be displayed.

Specifications

  • Display: 3½digits LCD with maximum reading 1999, Plus decimal point, unit symbol indication.
  • Overload Indication: LCD will show a “1” in the left highest position.
  • Low Battery Indication: Replace battery as LCD display “ ”.
  • Sampling Rate: 2 times per second for digital display.
  • Jaws opening:Max. 36mm
  • Conductor size:Max. 35mm
  • Dimension: 218mm(L)x75mm(W)x43mm(H).
  • Weight:about 360g. (Including battery)

Electrical Specifications
DC CURRENT
Range Resolution Accuracy Overload
Protection
200A 0.1A ±(1.5%+5) 800A rms
(60 second)
600A 1A ±(2.0%+5)
 
ACV CURRENT
Range Resolution Accuracy
40Hz~65Hz
Overload Protection
200A 0.1A ±(2.0%+5) 800V rms
(60 second)
600A 1A
 
DC VOLTAGE
Range Resolution  Accuracy Overload Protection
200V 0.1V ±(1.0%+3) 600V rms
600V 1V
 
AC VOLTAGE
Range Resolution  Accuracy Overload Protection
200V 0.1V ±(1.2%+5) 600V rms
600V 1V
 
RESISTANCE
Range Resolution  Accuracy Max. Open Voltage Overload Protection
2KΩ 1Ω ±(1.0%+3) 0.4VDC 550V rms
200KΩ 0.1KΩ
 
CONTINUITY TEST
Range Resolution  Accuracy Test Voitage Overload
Protection
1mV ±(1.0%+2) <3.3V 550V rms
※Also with buzz function for continuity purpose,buzz will sound
when the measured resistance is below 40Ω
DOIDE CHECK
Range Resolution  Test Voitage Overload Protection
  1mV <3.3V 550V rms
 
FREQUENCY(Auto-range)
Range Resolution Accuracy Max. Sensitivity Overload Protection
2KHz 1Hz ±(0.5%+3) 1.5V rms 550Vrms
20KHz 10Hz
200KHz 100Hz


 

View more about Tenmars TM-24E AC/DC Clamp Meter on main site