Benetech GM531 Infrared thermometer

Benetech GM531 Infrared thermometer


Specifications
Details

This unit consist of Optics, Temperature Sensor Signal amplifier, Processing circuit and LCD Display. 

The Optics collected the infrared energy emitted by object and focus onto the Sensor. 

Then the sensor translates the energy into an electricity signal.  This signal will be turned out to be digital shown on the LCD after the signal amplifier and processing circuit.


Infrared thermometer possesses the following features:
1.℃ / ℉ temperature unit conversion
2.Data retention
3.Positioning laser
4.LCD backlight
5.Max / Min display
6.Self-calibration
7.Ambient temperature view
8.Automatic shut-down

Specifications:
Temperature range      GM531: -50~530℃ (-58~986℉)     
Accuracy      0~400℃/530 (32~752℉/986 ) :     
±1.5℃(±2.7℉) or ±1.5%
-50~0℃(-58~32℉):±3℃ (±5℉)     
Whichever is greater
 
Repeatability      1% of reading or 1℃     
Response time      500 mSec, 95% response     
Spectral response      5~14 um     
Emissivity      0.10~1.00optional (0.95 Preset)     
Distance to Spot size      12:1     
Operating Temperature      0 ~40℃ (32 ~ 104℉)     
Operating Humidity      10~95%RH non-condensing,     
up to 30℃(86℉)
 
Storage Temperature      -20 ~ 60℃ (-4~140℉)     
Power      3V (1.5V AAA  * 2)     
Typical battery life (Alkaline)       Laser Models:12 hrs     

Accessories:
- 1.5V battery*2
- Host*1
- Blister packaging*1
- Instructions*1

View more about Benetech GM531 Infrared thermometer on main site