The Smart Sensor AR8407 is a portable multifunction water-quality detector designed for applications requiring several commonly monitored parameters in one system.
It covers:
Dissolved Oxygen (DO)
pH
Ammonia Nitrogen
Nitrite
Temperature
This makes AR8407 particularly relevant to aquaculture, fish farming, shrimp farming, hatcheries, laboratory testing, agriculture, environmental monitoring and field water-quality inspection.
Before buying, however, compare its specifications with your actual measurement requirements.
Smart Sensor AR8407 Specifications
Parameter / FeatureSpecificationDissolved Oxygen Range0–30.0 mg/LDO Resolution0.1 mg/LDO Accuracy±3.0% FSpH Range3.5–11.0pH Resolution0.1pH Accuracy±0.2Ammonia Nitrogen Range0–1.00 mg/LAmmonia Resolution0.01 mg/LAmmonia Accuracy±5% or 0.01 mg/LNitrite Range0–1.00 mg/LNitrite Resolution0.01 mg/LNitrite Accuracy±5% or 0.01 mg/LTemperature Range0–50°CTemperature Accuracy±0.5°CSalinity Compensation0–42 pptAltitude Compensation0–3500 mData Storage99 Groups – ManualDO Probe CableApprox. 3.5 mPower Supply4 × AAA BatteriesDisplayBacklit DisplayAuto Power OffApprox. 1 Hour
What Does AR8407 Actually Measure?
AR8407 provides five key measurements:
1. Dissolved Oxygen
Range:
0–30.0 mg/L
Resolution:
0.1 mg/L
Accuracy:
±3.0% FS
DO is particularly important for:
Fish Farms
Shrimp Farms
Hatcheries
RAS Systems
Environmental Water Monitoring
2. pH
Range:
3.5–11.0
Resolution:
0.1
Accuracy:
±0.2
pH provides important information about water conditions and is particularly useful when interpreted together with:
Temperature
and:
Ammonia Nitrogen
3. Ammonia Nitrogen
Range:
0–1.00 mg/L
Resolution:
0.01 mg/L
Accuracy:
±5% or 0.01 mg/L
For aquaculture applications, ammonia monitoring can help investigate changes related to:
Feed loading
Fish waste
Stocking density
Organic accumulation
Biological filtration
Water management
4. Nitrite
Range:
0–1.00 mg/L
Resolution:
0.01 mg/L
Accuracy:
±5% or 0.01 mg/L
A simplified nitrogen pathway is:
Ammonia → Nitrite → Nitrate
This makes ammonia and nitrite useful parameters to monitor together when investigating nitrogen-related changes.
5. Temperature
Range:
0–50°C
Accuracy:
±0.5°C
Temperature provides important context for:
DO
Aquaculture conditions
Biological activity
Ammonia interpretation
It should not be treated as an unimportant secondary reading.
Important: Understand the AR8407 Measurement Methods
This is one of the most important points before purchasing.
AR8407 is a multifunction water-quality instrument.
However:
It does not mean one electronic probe simultaneously measures every listed parameter.
The dissolved oxygen measurement uses the DO probe system.
The pH, ammonia nitrogen and nitrite functions use their corresponding test/reagent procedures specified for the AR8407.
Therefore, buyers should understand the actual testing workflow before choosing the instrument.
AR8407 Dissolved Oxygen Probe
The DO probe cable is approximately:
3.5 metres
This is useful for field applications where the measurement point may not be immediately beside the operator.
Examples include:
Fish ponds
Shrimp ponds
Large tanks
Hatchery tanks
Reservoirs
Treatment tanks
Environmental sampling points
For aquaculture users, cable length can be an important practical specification.
Automatic Temperature Compensation
AR8407 provides:
Automatic Temperature Compensation
for its dissolved oxygen measurement system.
Temperature affects DO conditions, so temperature compensation is an important part of practical DO measurement.
Salinity Compensation
AR8407 provides:
Salinity Compensation: 0–42 ppt
This is particularly relevant when DO is measured under different salinity conditions.
However, buyers must understand:
Salinity compensation does NOT mean AR8407 measures salinity.
If you require an actual salinity reading, use an appropriate salinity meter or multi-parameter instrument that includes salinity measurement.
Altitude Compensation
AR8407 provides:
Altitude Compensation: 0–3500 m
Altitude can influence dissolved oxygen measurement conditions.
This compensation function allows the instrument to account for different elevations within its specified operating capability.
99 Groups of Manual Data Storage
AR8407 supports:
99 groups of manually stored data.
This can be useful when checking:
Multiple ponds
Multiple tanks
Several sampling points
Different treatment stages
For example:
Pond 01 → Reading
Pond 02 → Reading
Pond 03 → Reading
Tank 01 → Reading
Tank 02 → Reading
For long-term monitoring, users should still maintain organized external records.
Backlit Display
The instrument includes a:
Backlit display
which can improve readability during field use and lower-light inspection conditions.
For aquaculture users performing early-morning DO checks, display visibility can be a practical consideration.
Battery Power
AR8407 uses:
4 × AAA batteries
This supports portable field use without requiring a permanent power supply at each pond or tank.
That can be useful for technicians travelling between multiple monitoring locations.
Automatic Power-Off
The instrument provides automatic power-off after approximately:
1 hour
This helps reduce unnecessary battery consumption during field use.
Who Is AR8407 Designed For?
Potential users include:
Fish Farmers
Shrimp & Prawn Farmers
Aquaculture Technicians
Fish Hatcheries
Aquaculture Nurseries
RAS Operators
Agricultural Projects
Environmental Monitoring Teams
Laboratories
Research Applications
The actual suitability depends on required range, method and accuracy.
Is AR8407 Suitable for Fish Farming?
AR8407 is particularly attractive when a fish farm needs routine portable measurements of:
DO
pH
Ammonia
Nitrite
Temperature
Instead of carrying only a DO meter, the operator can investigate several related water-quality conditions.
This can be useful for:
Routine monitoring
Troubleshooting
Multiple-pond inspection
Before/after operational checks
Is AR8407 Suitable for Shrimp Farming?
AR8407 can be useful for shrimp and prawn farms requiring:
DO + pH + Ammonia + Nitrite + Temperature
Its DO system also includes:
0–42 ppt salinity compensation.
But remember:
AR8407 does not provide actual salinity measurement.
Shrimp farms that need salinity readings should add a suitable salinity meter.
Is AR8407 Suitable for RAS?
For RAS applications, AR8407 can serve as a:
Portable Spot-Check Meter
Troubleshooting Instrument
Multi-Point Inspection Tool
Verification Meter
Operators can compare measurements at:
Culture Tank
Biofilter Inlet
Biofilter Outlet
Aeration Section
Return Water
Critical RAS systems may still require fixed continuous sensors and automatic alarms.
AR8407 vs Dedicated DO Meter
Choose a dedicated DO meter when:
✓ DO is the primary requirement
✓ You require specialized DO specifications
✓ You already own separate water-quality instruments
✓ You want a dedicated backup DO meter
Consider AR8407 when:
✓ DO is required
✓ pH is also required
✓ Ammonia monitoring is required
✓ Nitrite monitoring is required
✓ Portable multi-parameter testing is preferred
AR8407 vs Basic pH Meter
If your only requirement is pH:
Buy an appropriate pH meter.
If your requirement is:
pH + DO + Ammonia + Nitrite + Temperature
then AR8407 becomes much more relevant.
Do not choose based on the number of functions alone.
Choose based on your actual monitoring requirements.
What AR8407 Does NOT Replace
AR8407 should not automatically be treated as a replacement for:
Continuous Online DO Monitoring
Automatic Alarm Systems
Laboratory Analytical Equipment
Regulatory-Specified Testing Methods
Dedicated Salinity Meter
EC Meter
TDS Meter
Turbidity Meter
Different applications require different equipment.
5 Things to Check Before Buying AR8407
1. Measurement Parameters
Do you actually need:
DO + pH + Ammonia + Nitrite + Temperature?
If yes, AR8407 deserves consideration.
2. Measurement Range
Check:
Ammonia: 0–1.00 mg/L
Nitrite: 0–1.00 mg/L
against your expected sample concentrations.
3. Measurement Method
Understand that pH, ammonia and nitrite use their specified test/reagent procedures.
4. Portable or Continuous?
AR8407 is designed for portable testing.
If you need:
24/7 monitoring + alarms
consider a continuous monitoring system.
5. Additional Parameters
Ask whether you also need:
Salinity
EC
TDS
Turbidity
or other parameters.
If yes, additional instruments may be required.
AR8407 Buying Decision
AR8407 makes the most sense when the requirement is:
Portable
Multiple Sampling Locations
DO
pH
Ammonia Nitrogen
Nitrite
Temperature
This is a strong combination for general aquaculture field monitoring.
When Should You Choose Another Model?
Choose another instrument when:
Required range falls outside AR8407 specifications
Higher or specialized accuracy is required
A specific analytical method is required
Continuous measurement is required
Actual salinity measurement is required
EC/TDS/turbidity is the main requirement
The correct instrument is the one that matches the application—not necessarily the model with the most functions.
Smart Sensor AR8407 Supplier Malaysia
MTM Precision supplies the Smart Sensor AR8407 Multifunction Water Quality Meter for applications including:
Aquaculture
Fish Farming
Shrimp Farming
Fish Hatcheries
RAS Systems
Agriculture
Environmental Monitoring
Laboratory & Field Water Testing
MTM Precision also supplies instruments for:
Dissolved Oxygen
pH
EC
TDS
Salinity
Ammonia
Nitrite
Turbidity
and other water-quality parameters.
Before purchasing AR8407, send us:
1. Application
2. Water type
3. Parameters required
4. Expected measurement range
5. Number of ponds or tanks
6. Portable or continuous monitoring requirement
We can help determine whether Smart Sensor AR8407 or another water-quality instrument better matches your application.
Contact MTM Precision
MTM Precision Sdn Bhd
Website: www.mtmpre.com.my
Email: mtmpre@yahoo.com
WhatsApp: 016-660 7346
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
Supplying water-quality testing instruments across Selangor, Kuala Lumpur, Johor, Penang, Perak, Melaka, Negeri Sembilan, Pahang, Kedah, Perlis, Terengganu, Kelantan, Sarawak and Sabah.
Sep 09,2026