Linshang LS200 Insulated Glass Thickness Meter for Double Glazing Malaysia

Linshang LS200 Insulated Glass Thickness Meter for Double Glazing Malaysia

 

How can you check the thickness of insulated glass or double glazing after it has already been installed?

 

For glass contractors, window companies, building inspectors and maintenance teams, this can be difficult because the edges of the glass are usually hidden inside the frame.

 

The Linshang LS200 Glass Thickness Meter provides a practical solution. Using the laser reflection principle, it can measure glass thickness from one side and can also determine the glass thickness and air interlayer thickness of insulated glass simultaneously.

 

This makes the Linshang LS200 particularly useful for double glazing and insulated glass inspection in Malaysia.

 

What Is Insulated Glass?

 

Insulated glass is commonly constructed using multiple glass panes separated by an air space.

 

The space between the glass layers contributes to the overall construction of the insulated glass unit.

 

When inspecting an existing installation, professionals may therefore need to know more than just the total thickness.

 

They may need to determine:

 

Thickness of the glass

 

Air space between the glass layers

 

General configuration of the insulated glass unit

 

This becomes more challenging after the unit has been installed into a window or building structure.

 

Why Is Double Glazing Difficult to Measure?

 

With loose glass, the edge can often be measured directly.

 

With installed double glazing, the situation is different.

 

The edges may be covered by:

 

Aluminium window frames

 

Door frames

 

Glazing beads

 

Sealants

 

Curtain wall systems

 

Fa莽ade structures

 

Access to the opposite side may also be restricted.

 

Removing an insulated glass unit just to determine its basic dimensions is often inconvenient.

 

The Linshang LS200 is designed for this type of application.

 

Measure Insulated Glass from One Side

 

One of the main advantages of the Linshang LS200 Glass Thickness Meter is its one-side measurement capability.

 

The instrument uses laser reflections from the glass surfaces.

 

By observing the reflected laser lines and reading the scale, users can determine the relevant glass dimensions without requiring access to both sides.

 

This is especially valuable for installed windows and building glazing.

 

Measure Glass and Air Interlayer Simultaneously

 

For insulated glass applications, measuring only the glass pane may not provide enough information.

 

The Linshang LS200 can be used to measure:

 

Glass thickness + air interlayer thickness

 

This capability helps users better understand the construction of an existing insulated glass unit.

 

For example, a contractor preparing a replacement window may need to identify the approximate existing configuration before selecting or ordering the replacement glazing.

 

The LS200 provides a convenient on-site method for carrying out this inspection.

 

Linshang LS200 Measurement Scales

 

The Linshang LS200 incorporates dedicated scales for glass and air-space measurement.

 

Glass Thickness Scale

 

70 mm

 

This scale is used for glass thickness measurement based on the reflected laser positions.

 

Air Space Scale

 

34 mm

 

This scale allows users to determine the air interlayer thickness in insulated glass applications.

 

The combination makes the LS200 particularly useful when working with double glazing.

 

Application: Replacement of Existing Double-Glazed Windows

 

Consider a building where several insulated glass panels need replacement.

 

The building owner may no longer have the original glazing specifications.

 

Removing multiple panels simply to investigate their construction would create unnecessary work.

 

A glass contractor can use the Linshang LS200 Glass Thickness Meter from the accessible surface to inspect the glass and air-space dimensions.

 

The information obtained can help the contractor understand the existing glazing configuration before proceeding with replacement planning.

 

Application: Building and Property Inspection

 

Building inspectors and maintenance teams may also encounter windows where the original documentation is unavailable.

 

The LS200 provides a practical tool for investigating the installed glazing without requiring destructive inspection.

 

Potential locations include:

 

Commercial buildings

 

Office windows

 

Residential properties

 

Shopping complexes

 

Hotels

 

Factories

 

Building fa莽ades

 

Glass doors

 

Fixed windows

 

Curtain wall systems

 

This makes a portable glass thickness meter useful beyond the glass manufacturing industry itself.

 

Application: Window and Door Contractors

 

Window and door contractors frequently work with existing installations.

 

During renovation or replacement projects, identifying the existing glass configuration can be important.

 

The Linshang LS200 allows contractors to perform measurements directly on site rather than relying only on visual estimation.

 

This can be particularly helpful for insulated glass where the internal air-space dimension is not easily measured mechanically after installation.

 

Linshang LS200 for Curtain Wall and Fa莽ade Inspection

 

Curtain wall glass presents another challenging measurement situation.

 

Accessing both sides of fa莽ade glazing may be difficult, particularly on completed buildings.

 

The one-side measurement principle of the Linshang LS200 therefore offers an important practical advantage.

 

Inspectors can perform the measurement from the accessible surface without needing to physically reach the opposite side simply to determine glass thickness.

 

Linshang LS200 vs Basic Glass Thickness Measurement

 

For ordinary loose glass, a mechanical measuring tool may be sufficient.

 

For installed insulated glass, however, the inspection requirement becomes more complicated.

 

A basic mechanical measurement may require access to the glass edge.

 

The Linshang LS200 Glass Thickness Meter is specifically useful when:

 

Glass is already installed

 

Only one side is accessible

 

The glass edge is covered

 

Air-space thickness needs to be checked

 

Insulated glass construction is unknown

 

Existing glazing specifications are unavailable

 

This is where laser reflection measurement becomes particularly valuable.

 

Who Can Use the Linshang LS200?

 

The Linshang LS200 is suitable for professionals such as:

 

Glass suppliers

 

Glass manufacturers

 

Window contractors

 

Door contractors

 

Double-glazing specialists

 

Fa莽ade contractors

 

Building inspectors

 

Construction QA/QC teams

 

Property maintenance companies

 

Facility management teams

 

Glass replacement contractors

 

Looking for an Insulated Glass Thickness Meter in Malaysia?

 

The Linshang LS200 Glass Thickness Meter provides a convenient solution for measuring installed glass and insulated-glass air spaces from one side.

 

Its combination of laser reflection measurement, 70 mm glass thickness scale and 34 mm air-space scale makes it a practical inspection tool for glass professionals, contractors and building maintenance applications.

 

For enquiries about the Linshang LS200 Glass Thickness Meter in Malaysia, contact MTM Precision.

 

Contact MTM Precision

 

MTM Precision Sdn. Bhd.

 

Showroom & Service Centre

 

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia

 

🌐 Website: www.mtmpre.com.my

📧 Email: mtmpre@yahoo.com

📱 WhatsApp: +6016-660 7346

 

Contact MTM Precision for Linshang LS200 Glass Thickness Meter Malaysia.


 

Aug 13,2026